Grandstream gateway for Faxing

Modified on Wed, 30 Jul at 4:32 PM

Applies to models such as HT801, HT802, HT812, HT814, HT818


Step 1: Log In to the Web Interface

  1. Connect a PC to the same network as the ATA device.

  2. Find the IP address of the ATA (pick up the handset connected to FXS port and dial *** → then dial 02 to hear IP).

  3. Open a browser and go to: http://[DEVICE_IP]

  4. Log in (default credentials:

    • Username: admin

    • Password: admin


Step 2: Navigate to FXS Port Settings

  1. Go to the "FXS Port" tab (e.g., FXS Port 1, FXS Port 2, etc.).

  2. Configure the following:


SIP Settings

Field
Value
Primary SIP Server
SIP User ID
YOUR_USER_ID
Authenticate ID
YOUR_USER_ID
Authenticate Password
YOUR_PASSWORD
Name
Fax
SIP Registration
Yes
Outgoing Call Without Reg
No
Unregister on Reboot
Yes
Register Expiration
3
Enable SIP OPTIONS Keep Alive
Yes
Use Random SIP Port
Yes
Use Random RTP Port
Yes



Call Waiting / Tone Handling

Feature
Setting
Disable Call-Waiting
Yes
Disable Call-Waiting Caller ID
Yes
Disable Call-Waiting Tone
Yes
Use First Matching Vocoder in 200OK SDP
Yes


Audio Codec Preferences

Set the Preferred Vocoder list (in order):

  1. PCMA

  2. PCMU

  3. PCMA

  4. PCMA

  5. PCMA

  6. PCMA

  7. PCMA


Field
Value
iLBC Frame Size
20ms
VAD
No
Symmetric RTP
No


Fax Settings

Setting
Value
Fax Mode
T.38
Re-INVITE After Fax Tone Detected
Enabled


Buffer & Echo Settings

Field
Value
Jitter Buffer Type
Adaptive
Jitter Buffer Length
High
SLIC Setting
AUSTRALIA
Gain
TX 0dB, RX -12dB
Disable Line Echo Canceller
Yes
Disable Network Echo Suppressor
Yes


Step 3: Configure Regional Tones

  1. Go to Advanced Settings tab

  2. Scroll to Custom Ring Tone & Dial Tone Settings

  3. Insert the following tone strings into respective fields:

Tone Type
Value
Dial Tone
f1=425@-11,f2=0@-11,c=0/0;
Ringback Tone
f1=440@-17,f2=480@-17,c=2000/4000;
Busy Tone
f1=425@-11,f2=0@-11,c=37/37;
Reorder Tone
f1=425@-11,f2=0@-11,c=37/37;
Confirmation Tone
f1=350@-11,f2=440@-11,c=100/100-100/100-100/100;
Call Waiting Tone
f1=440@-13,c=300/10000;
Prompt Tone
f1=350@-17,f2=440@-17,c=0/0;

Step 4: Save & Apply Settings

  1. Scroll to the bottom of the configuration page.

  2. Click Update or Apply.

  3. When prompted, reboot the ATA to apply settings.

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article